| Materials |
| 1 |
Concrete: Steel-reinforced, polypropylene fibre reinforced 4000 psi minimum 38 day comprehensive strength, air-entrained (ASTM C260). |
| 2 |
Reinforcing Steel: ASTM A615, grade 400 unless otherwise indecated. |
| 3 |
Reinforcing Fibre: Fibrillated polypropylene fibre, Fibermesh, or equal @ 1.6 pounds per cubic yard, or equal. |
| 4 |
Post = tensioning strand: 41K polystrand CP50, .50" 270 KSI, 7 wire strand, greased plastic shelath, (ASTM A416). Roof and floor each to be post-tensioned by a single continuous tendon. Said tendon shall form a substantially rectangular in roof configuration having three gently curving corners and a fourth corner where the tendon members are anchored. Tendons shall be greased and enclosed within a shealth. |
| 5 |
Panel Connections: All panels shall be securely fastened together with 1/4" thick steel brackets. Steel is to be of structural quality, hot-rolled carbon complying with ASTM A283, Grade C. All fasteners to be ?" diameter bolts. Cast-in anchors used for panel connections to be Dayton-Superior F-63 or equal. |
| 6 |
Doors and Frames: As per spec - or as per quote: Shall comply with Steel Door Institute, "Recommended Specifications for Steel Doors and Frames" (SDI-100) and as herein specified. The building shall be equipped with two 3' -0" x 7'-0" 18 gauge metal doors with lockseam construction and honeycomb insulation or equal. Door frames shall be 16 gauge wipe coat galvanized an painted on coat of Industrial Grey, unless colour is specifed. |
| 7 |
Standard Door Hardware: (See Options on Building Worksheet) |
|
A |
Hinges: Stanley BB#1409, 4' - ½" x 4" x NRP x PT with Non-removable pins. |
|
B |
Lockset: Ingersoll-Rand R160N x 626, or equal |
|
C |
Threshold: K.N. Crowder CTG x 4" Aluminum. |
|
D |
Door Sweep: K.N. Crowder W13-S Aluminum with Neoprene inserts, or equal. |
|
E |
Surface Bolt Upper: Magnokrom #400 / 401 x 32D, or equal. |
|
F |
Surface Bolt Lower: Magnokrom #400 / 401 x 32D, or equal. |
|
G |
Astragal: P4441 / 68R, or equal. |
| 8 |
Vents: Two Metalines #M-22FL, or equal, extruded aluminium flanged vents 15-5/8" standard #204 clear finish with 8 x 8 mesh x .028 diameter aluminium insect screen. |
| 9 |
Caulking: All joints between panels shall be caulked on exterior and interior surfaces. Caulking shall be Tremco 830 or equal, elastomeric sealant, polyurethane-base, limestone colour. |
| 10 |
Curing and Sealing: |
|
A |
All precast concrete surfaces will be treated with Sealtite CS-309, non-yellowing curing compound. |
|
B |
All exposed aggregate exterior precast surfaces will be treated with Hydro-Tight invisible silicone coating. |
|
C |
All non-exposed aggregrate exterior surfaces will be treated with Externit #50 special grey coating. |